Previous Article | Next Article ![]()
Infect Immun. 1979 December; 26(3): 827-831
ABSTRACT
Rapid diagnosis of Haemophilus influenzae type b meningitis is possible using immunological tests for capsular antigen (polyribophosphate, PRP), such as countercurrent immunoelectrophoresis (CIE) and latex particle agglutination (LPA). We compared two tests in monkeys with evolving, serially quantitated H. influenzae type b bacteremia (n = 23) and meningitis (n = 21). In vitro, the LPA test was sensitive to 0.5 ng of PRP/ml of saline, and the CIE test was sensitive to 1.0 ng/ml; in serum, however, CIE detected 5.0 ng of PRP/ml, whereas the sensitivity of LPA was unchanged. LPA detected PRP earlier in the course of bacteremia (mean, 12 h after onset; range, 4 to 36 h) than did CIE (mean, 45 h; range, 4 to 168 h) (P less than 0.01). A positive LPA test required greater than or equal to 100 bacteria per ml of blood, whereas CIE required greater than or equal to 1,000/ml. PRP accumulated with continuing blood stream infection, aiding detection of low-grade bacteremia. LPA detected antigen in cerebrospinal fluid (CSF) earlier in the course of meningitis and at a lower bacteria density than did CIE. Both methods detected antigen reliably with greater than or equal to 1,000 bacteria per ml of CSF. A close correlation existed between CSF concentrations of capsular antigen and bacteria (r = 0.90, P less than 0.001). We conclude that the LPA method permits earlier diagnosis of H. influenzae type b infection in part because of its greater sensitivity.
This article has been cited by other articles:
| J. Bacteriol. | J. Virol. | Eukaryot. Cell |
|---|
| Microbiol. Mol. Biol. Rev. | Clin. Vaccine Immunol. | All ASM Journals |
|---|