IAI FigSearch
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Dreesman, G. R.
Right arrow Articles by Melnick, J. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dreesman, G. R.
Right arrow Articles by Melnick, J. L.
Infect Immun. 1972 February; 5(2): 213-221
Copyright © 1972 American Society for Microbiology. All Rights Reserved.

Production of Potent Anti-Australia Antigen Sera of High Specificity and Sensitivity in Goats

Gordon R. Dreesman, F. Blaine Hollinger, Robert M. McCombs and Joseph L. Melnick

Department of Virology and Epidemiology, Baylor College of Medicine, Houston, Texas 77025

ABSTRACT

Potent antisera of high specificity and sensitivity were produced, in goats, to purified Australia antigen (Au). The antigen was prepared by one of three methods: (i) pelleting, low pH treatment, isopycnic centrifugation two times in CsCl, and rate zonal centrifugation in sucrose; (ii) same as procedure i, with the exception of the low pH treatment; or (iii) twice banding in CsCl by using a BXIV batch-type zonal centrifuge rotor with subsequent preparative Pevikon electrophoresis. The goat anti-Au sera contained high levels of precipitating antibody as tested by immunodiffusion in agar gel and discontinuous counterimmunoelectrophoresis (DCIE) as well as specific complement-fixing antibody and could be used for routine screening of sera for Au without prior adsorption with Au-negative normal human serum (NHS). Identification of 66 of 70 positive specimens (94.3%) in a panel of 98 coded sera (49 duplicates) with 100% reproducibility was made by using one of the goat anti-Au sera at a dilution of 1:16 in the DCIE method. No false positives were recorded. Low levels of antibody against NHS components were effectively removed by a single adsorption with glutaraldehyde cross-linked NHS.


Infect Immun. 1972 February; 5(2): 213-221
Copyright © 1972 American Society for Microbiology. All Rights Reserved.







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
J. Bacteriol. J. Virol. Eukaryot. Cell
Microbiol. Mol. Biol. Rev. Clin. Vaccine Immunol. All ASM Journals

Copyright © 1972 by the American Society for Microbiology. All rights reserved.