IAI FigSearch
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kenny, G. E.
Right arrow Articles by Foy, H. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kenny, G. E.
Right arrow Articles by Foy, H. M.

 Previous Article  |  Next Article 

Infect Immun. 1972 October; 6(4): 431-437
Copyright © 1972 American Society for Microbiology. All Rights Reserved.

Correlation of Circulating Capsular Polysaccharide with Bacteremia in Pneumococcal Pneumonia

George E. Kenny, Berttina B. Wentworth, R. Palmer Beasley and Hjordis M. Foy

1 Department of Pathobiology and Department of Epidemiology and International Health, University of Washington, School of Public Health and Community Medicine, Seattle, Washington 98195

ABSTRACT

Immunoelectroosmophoresis with rabbit anticapsular antibody was used to detect type-specific pneumococcal polysaccharide in serum from bacteremic patients with pneumococcal pneumonia. The test could detect as little as 0.1 to 1.0 µg per ml or 0.2 to 2 ng per test of polysaccharide from types 1, 2, 3, 4, 5, 8, 12, and 18, and its sensitivity was 10 times that of double immunodiffusion. Although antigen could be detected by double immunodiffusion with types 7 and 14, no antigen could be detected by immunoelectroosmophoresis. Types 7 and 14 polysaccharides were found to be positively charged, whereas the other polysaccharides were negatively charged. Forty-six patients with pneumonia were selected for study because pneumococci corresponding to those types where the test was known to work had been isolated from blood or the respiratory tract. Antigenemia correlated strongly with bacteremia: 12 of 20 bacteremic patients with pneumonia showed antigenemia, whereas 26 patients negative for bacteremia did not show circulating antigen detectable with antisera against the pneumococcal type isolated from the respiratory tract. The apparent concentration of circulating polysaccharide ranged from 0.1 to 100 µg per ml of serum, and the concentration did not appear to diminish appreciably in 10 to 15 days. Three of 12 patients with antigenemia died, and two of these had the highest levels of circulating antigen observed.


Infect Immun. 1972 October; 6(4): 431-437
Copyright © 1972 American Society for Microbiology. All Rights Reserved.







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
J. Bacteriol. J. Virol. Eukaryot. Cell
Microbiol. Mol. Biol. Rev. Clin. Vaccine Immunol. All ASM Journals

Copyright © 1972 by the American Society for Microbiology. All rights reserved.